Addresss
OUR CONTACT INFORMATION
Our business allows customers to have ODM/OEM service that fits their individual needs
Tel
201, 19th Building , 100 Jinxi Rd, Binhu District, Wuxi, Jiangsu, China
Factory Address
Factory: Shuangxin Industrial Park, Binhu District,Wuxi, JS, CN.
Copyright©: RexCo Technology
Powered By: www.300.cn
0086-18921182885
5kw MPPT controller
5kw MPPT Charge Controller Specification: (Buck and Boost)
Model |
WW50-48-240 |
WW50-120-240 |
WW50-240-240 |
Type |
Buck |
Boost |
|
Wind Turbine Input |
|||
Rated input power |
5kW |
||
Rated input voltage |
280Vdc |
||
Input voltage range |
0~320Vdc |
||
Start charge voltage |
60Vdc (factory default,40Vdc~320Vdc settable) |
||
Rated input current |
21Adc |
||
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
||
|
Switch “ON” the brake switch |
||
Brake by over current |
25A (factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
||
Brake by overvoltage |
320Vdc (factory default,220Vdc~320Vdc settable)PWM unload step by step once reached the set unload voltage, and it will unload completely if the voltage rise 20Vdc more. |
Refer to “output overvoltage” control |
|
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after 10mins (and the speed should be less than 15m/s.) |
||
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
||
Charge Parameters (optional) |
|||
Rated battery voltage |
48Vdc |
120Vdc |
240Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V |
||
Output Parameters |
|||
Rated output voltage |
48Vdc |
120Vdc |
240Vdc |
Start unload voltage |
56Vdc (factory default,44Vdc~64Vdc settable) |
140Vdc (factory default,110Vdc~160Vdc settable) |
280Vdc (factory default,220Vdc~320Vdc settable) |
Complete unload voltage |
60Vdc (factory default, add 4V to the start unload voltage) |
150Vdc (factory default, add 10V to the start unload voltage) |
300Vdc (factory default,add 20V to the start unload voltage) |
Max. Output current |
105Adc |
42Adc |
21Adc |
General Parameters |
|||
Rectifier mode |
Uncontrolled rectifier |
||
Display mode |
LCD |
||
Display information |
DC output voltage, wind turbine voltage/current/power. |
||
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/WIFI/Bluetooth/Zigbee |
||
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. |
||
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
|||
Lightning protection |
YES |
||
Conversion efficiency |
≥95% |
||
Static loss |
<8W |
<6W |
|
Ambient temperature |
-20℃~+40℃ |
||
Humidity |
≤90%, No condensing |
||
Noise |
≤65dB |
||
Cooling mode |
Natural cooling |
||
Installation mode |
Wall-mounted |
||
Cover protection class |
IP42 |
||
Product dimension (W*H*D) |
360×430×191mm |
||
Product net weight |
13kg |
||
Dump load dimension (W*H*D) |
730×390×190mm |
||
Dump load net weight |
19kg |
||