Call Us Now + 0086-18921182885
PRODUCT CENTER
focus on wind turbine, permanent magnet generafor, solar panel, controllers design and producing for decade.
Description
5kw MPPT Charge Controller Specification: (Buck and Boost)
|
Model |
WW50-48-240 |
WW50-120-240 |
WW50-240-240 |
|
Type |
Buck |
Boost |
|
|
Wind Turbine Input |
|||
|
Rated input power |
5kW |
||
|
Rated input voltage |
280Vdc |
||
|
Input voltage range |
0~320Vdc |
||
|
Start charge voltage |
60Vdc (factory default,40Vdc~320Vdc settable) |
||
|
Rated input current |
21Adc |
||
|
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
||
|
|
Switch “ON” the brake switch |
||
|
Brake by over current |
25A (factory default,0~25A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
||
|
Brake by overvoltage |
320Vdc (factory default,220Vdc~320Vdc settable)PWM unload step by step once reached the set unload voltage, and it will unload completely if the voltage rise 20Vdc more. |
Refer to “output overvoltage” control |
|
|
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after 10mins (and the speed should be less than 15m/s.) |
||
|
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
||
|
Charge Parameters (optional) |
|||
|
Rated battery voltage |
48Vdc |
120Vdc |
240Vdc |
|
Temperature compensation function (optional) |
-3mV/℃/2V |
||
|
Output Parameters |
|||
|
Rated output voltage |
48Vdc |
120Vdc |
240Vdc |
|
Start unload voltage |
56Vdc (factory default,44Vdc~64Vdc settable) |
140Vdc (factory default,110Vdc~160Vdc settable) |
280Vdc (factory default,220Vdc~320Vdc settable) |
|
Complete unload voltage |
60Vdc (factory default, add 4V to the start unload voltage) |
150Vdc (factory default, add 10V to the start unload voltage) |
300Vdc (factory default,add 20V to the start unload voltage) |
|
Max. Output current |
105Adc |
42Adc |
21Adc |
|
General Parameters |
|||
|
Rectifier mode |
Uncontrolled rectifier |
||
|
Display mode |
LCD |
||
|
Display information |
DC output voltage, wind turbine voltage/current/power. |
||
|
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/WIFI/Bluetooth/Zigbee |
||
|
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. |
||
|
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
|||
|
Lightning protection |
YES |
||
|
Conversion efficiency |
≥95% |
||
|
Static loss |
<8W |
<6W |
|
|
Ambient temperature |
-20℃~+40℃ |
||
|
Humidity |
≤90%, No condensing |
||
|
Noise |
≤65dB |
||
|
Cooling mode |
Natural cooling |
||
|
Installation mode |
Wall-mounted |
||
|
Cover protection class |
IP42 |
||
|
Product dimension (W*H*D) |
360×430×191mm |
||
|
Product net weight |
13kg |
||
|
Dump load dimension (W*H*D) |
730×390×190mm |
||
|
Dump load net weight |
19kg |
||
|