3kw MPPT Controller
3kw MPPT Charge Controller Specification: (Buck & Boost)
Model |
WW30-48-240 |
WW30-120-120 |
WW30-240-240 |
Type |
Buck |
Boost |
|
Wind Turbine Input |
|||
Rated input power |
3kW |
||
Rated input voltage |
280Vdc |
140dc |
280Vdc |
Input voltage range |
0~320Vdc |
0~160Vdc |
0~320Vdc |
Start charge voltage |
60Vdc (factory default,40Vdc~320Vdc settable) |
30Vdc (factory default,20Vdc~160Vdc settable) |
60Vdc (factory default,40Vdc~320Vdc settable) |
Rated input current |
13Adc |
25Adc |
13Adc |
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
||
|
Switch “ON” the brake switch |
||
Brake by over current |
15Adc (factory default,0~15A settable) |
30A (factory default,0~30A settable) |
15Adc (factory default,0~15A settable) |
Brake by overvoltage |
320Vdc (Factory default) |
Refer to “output overvoltage” |
|
Brake by over wind speed (optional) |
18m/s (0-30m/s settable) |
||
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable) |
||
Charge Parameters (optional) |
|||
Rated battery voltage |
48Vdc |
120Vdc |
240Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V |
||
Output Parameters |
|||
Rated output voltage |
48Vdc |
120Vdc |
240Vdc |
Start unload voltage |
56Vdc (factory default,44Vdc~64Vdc settable) |
140Vdc (factory default,110Vdc~160Vdc settable) |
280Vdc (factory default,220Vdc~320Vdc settable) |
Complete unload voltage |
60Vdc(factory default,add 4V to the start unload voltage) |
150Vdc (factory default,add 10V to the start unload voltage) |
300Vdc (factory default,add 20V to the start unload voltage) |
Max. Output current |
42Adc |
25Adc |
13Adc |
General Parameters |
|||
Rectifier mode |
Uncontrolled rectifier |
||
Display mode |
LCD |
||
Display information |
DC output voltage, wind turbine voltage/current/power. |
||
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee |
||
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. |
||
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
|||
Lightning protection |
YES |
||
Conversion efficiency |
≥92% |
||
Static loss |
<5W |
||
Ambient temperature |
-20℃~+40℃ |
||
Humidity |
≤90%, No condensing |
||
Noise |
≤65dB |
||
Cooling mode |
Natural cooling |
||
Installation mode |
Wall-mounted |
||
Cover protection class |
IP42 |
||
Product dimension (W*H*D) |
360×430×191mm |
300×375×145mm |
|
Product net weight |
13kg |
10kg |
|
Dump load dimension (W*H*D) |
400×390×210mm |
||
Dump load net weight |
12kg |
||
Note: the listed specs are just for your reference |