10kw MPPT Controller
10kw MPPT Charge Controller Specification:
Model |
WW100-240-240 |
Type |
Boost |
Wind Turbine Input |
|
Rated input power |
10kW |
Rated input voltage |
280Vdc |
Input voltage range |
0~320Vdc |
Start charge voltage |
60Vdc (factory default,40Vdc~320Vdc settable) |
Rated input current |
42Adc |
Brake by hand |
Keep press the button for 5s to unload completely, and then recover by hand. |
|
Switch “ON” the brake switch |
Brake by over current |
50A (factory default,0~50A settable)Unload completely when reached the set current, and recover automatically after working 10mins. |
Brake by overvoltage |
Refer to “output overvoltage” control |
Brake by over wind speed (optional) |
18m/s (0-30m/s settable), unload completely when reached the set wind speed, and recover automatically after 10mins (and the speed should be less than 15m/s.) |
Brake by over rotational Speed (optional) |
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins. |
Charge Parameters (optional) |
|
Rated battery voltage |
240Vdc |
Temperature compensation function (optional) |
-3mV/℃/2V |
Output Parameters |
|
Rated output voltage |
240Vdc |
Start unload voltage |
280Vdc (factory default,220Vdc~320Vdc settable) |
Complete unload voltage |
300Vdc (factory default,add 20V to the start unload voltage) |
Max. Output current |
42Adc |
General Parameters |
|
Rectifier mode |
Uncontrolled rectifier |
Display mode |
LCD |
Display information |
DC output voltage, wind turbine voltage/current/power. |
Monitoring mode (optional) |
RS232/RS485/RJ45/GPRS/WIFI/Bluetooth/Zigbee |
Monitoring Contents |
Real-time display: DC output voltage, wind turbine voltage/current/power. |
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button. |
|
Lightning protection |
YES |
Conversion efficiency |
≥95% |
Static loss |
<8W |
Ambient temperature |
-20℃~+40℃ |
Humidity |
≤90%, No condensing |
Noise |
≤65dB |
Cooling mode |
Natural cooling |
Installation mode |
Wall-mounted |
Cover protection class |
IP42 |
Product dimension (W*H*D) |
360×430×191mm |
Product net weight |
13kg |
Dump load dimension (W*H*D) |
520×550×430mm |
Dump load net weight |
45kg |